• High bond strength with High load resistance
  • Used with all grades of threaded rod and rebar in accordance with TR029
  • Ideal for deep embedment installations
  • Used in non-cracked, cracked, wet, or dry concrete and wood
  • Used in flood holes
  • Used for overhead applications
  • ETA approved for diamond drilled holes
  • Ideal for elevated temperatures ranging I, II, III
  • ETA approved for rebar installations under TR023 AND EN1992-1-1:2004 EC2
  • Zero shrinkage enables large diameter installations
  • ETA approved for Seismic Loads C2
  • Manual cleaning up to 20mm diameter and embedment depths of 240mm
  • Independently tested and approved
  • 24 month shelf life
  • A+ Rating VOC Content

Buffalo Pure Epoxy Solvent Free Chemical Anchor Resin 585ml

Code
PUR500585
30+ In Stock
  • High bond strength with High load resistance
  • Used with all grades of threaded rod and rebar in accordance with TR029
  • Ideal for deep embedment installations
  • Used in non-cracked, cracked, wet, or dry concrete and wood
  • Used in flood holes
  • Used for overhead applications
  • ETA approved for diamond drilled holes
  • Ideal for elevated temperatures ranging I, II, III
  • ETA approved for rebar installations under TR023 AND EN1992-1-1:2004 EC2
  • Zero shrinkage enables large diameter installations
  • ETA approved for Seismic Loads C2
  • Manual cleaning up to 20mm diameter and embedment depths of 240mm
  • Independently tested and approved
  • 24 month shelf life
  • A+ Rating VOC Content
£42.38 £35.32

Order 1x to earn 35 FASTPoints

Order to earn 35 FASTPoints

Log in to access trade discounts
30+ In Stock
Buffalo Pure Epoxy Solvent Free Chemical Anchor Resin 585ml
Buffalo Pure Epoxy Solvent Free Chemical Anchor Resin 585ml

Buffalo 500 is a 2 componant high strength pure epoxy chemical anchoring resin system. It is designed for deep embedment and large diameter holes due to its zero shrinkage, and longer working times. For diamond drilled holes, with rebar, and in areas of high chemical exposure e.g., Seasalt and swimming pools.

Approvals:

  • ETA Option 1 ETAG001 for cracked concrete with studs and rebar TR029
  • ETA Option 1 ETAG 001 for rebar TR023 - Approved for Seismic Loads C2
  • F120 Fire Test report-ICC-ES Approval ESR 3853
  • BS6920 for use with potable water WRAS Approved 1309522
  • ETA approved in flooded holes, wet and dry concrete
  • Tested according to LEED 2009 EQ c4, 1, SCAQMD rule 1168 (2005)

Minimum curing time

  • Concrete temperature: 5C
  • Gel-Working Time: 120 minutes
  • Minimum Curing Time In Dry Concrete: 3000 minutes
  • Minimum Cring Time In Wet Concrete: x2
  • Concrete Temperature: 15C
  • Gel-Working Time: 60 minutes
  • Minimum Curing Time  In Dry Concrete: 1200 minutes
  • Minimum Curing Time In Wet Concrrete: x2
  • Concrete Temperature: 25C
  • Gel-Working Time: 25 minutes
  • Minimum Curing Time In Dry Concrete: 480 minutes
  • Minimum Curing Time In Wet Concrete: x2
  • Concrete Temperature: 35C
  • Gel-Working Time: 16 minutes
  • Minimum Curing Time In Dry Concrete: 240 minutes
  • Minimum Curing Time In Wet Concrete: x2
  • Concrete Temperature: 40C
  • Gel-Working Time: 10 minutes
  • Minimum Curing Time In Dry Concrete: 150 minutes
  • Minimum Curing Time In Wet Concrete: x2
Reviews