Cable protection board for buried electric cables, built to warn and protect against accidental strikes during excavation and site works.

  • Heavy duty board for buried electric cable protection
  • High impact resistance against excavation strikes
  • Bright red and yellow warning colours with bold text
  • Rot resistant and chemically inert construction
  • Conforms to relevant internationally recognised standards
  • Made in the UK
  • Custom logo branding available

Cable Protection Board 1000 x 244mm - Caution Electric Cable Below

Code
SE190001
Out of Stock

Cable protection board for buried electric cables, built to warn and protect against accidental strikes during excavation and site works.

  • Heavy duty board for buried electric cable protection
  • High impact resistance against excavation strikes
  • Bright red and yellow warning colours with bold text
  • Rot resistant and chemically inert construction
  • Conforms to relevant internationally recognised standards
  • Made in the UK
  • Custom logo branding available
£13.08 £10.90
  • Buy 6 for £11.88 £9.90 each and save 9%
  • Buy 12 for £10.68 £8.90 each and save 18%
  • BULK DISCOUNT 6 12
    Price £9.90 £11.88 £8.90 £10.68

Order 1x to earn 10 FASTPoints

Order to earn 10 FASTPoints

Log in to access trade discounts
Out of Stock

Cable Protection Board 1000 x 244mm - Caution Electric Cable Below with Custom Logo Branding

Cable protection board designed to sit above buried electric cables, providing a clear visual warning and a physical barrier against accidental strikes during excavation or groundwork. The board's bright red and yellow colouring and bold Caution Electric Cable Below text give diggers and site operatives an unmistakable signal before they reach the cable itself. Made in the UK from a rot resistant, chemically inert material built for long service life underground.

How a visible, impact resistant board prevents accidental cable strikes

Buried electric cables are easy to strike accidentally during excavation, especially when ground conditions or old records make the exact cable position uncertain. A cable strike risks injury to the operative, damage to the cable and surrounding infrastructure, and significant repair and downtime costs. A brightly coloured, high impact protection board positioned above the cable gives a clear physical and visual warning before a digger or hand tool reaches the cable, reducing the risk of a strike.

Key Features

  • High impact resistance: Withstands accidental contact from digging equipment and hand tools without failing, adding a physical barrier above the cable.

  • Bold visual warning: Bright red and yellow colouring with Caution Electric Cable Below text gives an unmistakable signal before excavation reaches the cable.

  • Rot resistant and chemically inert: Holds up to prolonged underground exposure to moisture and soil chemistry without degrading.

  • Custom logo branding available: Utility companies and contractors can add their own logo to the board, supporting site branding and asset identification.

  • Made in the UK: Manufactured domestically, supporting consistent quality and supply for UK grid and utility projects.

  • Standard 1000 x 244mm size: Matches common UK cable protection board dimensions used across grid installation and utility works.

Who is this for

Trades and roles:

  • Utility contractors

  • Groundworkers

  • Electrical grid installers

  • Civil engineers

Industries:

  • Utilities and power distribution

  • Construction

  • Civil engineering

  • Telecommunications infrastructure

 Specifications

Specification Detail
Product Name Cable Protection Board 1000 x 244mm - Caution Electric Cable Below
SKU SE190001
Primary Function Buried electric cable protection board
Dimensions 1000mm x 244mm x 10mm
Impact Resistance High impact resistant
Warning Text Caution Electric Cable Below
Colour Red background with yellow warning text
Material Properties Rot resistant, chemically inert
Standards Compliance Conforms to relevant internationally recognised cable protection standards
Country of Manufacture United Kingdom

Compatibility

Compatible With Status
Underground electric cable protection ✓ Compatible
Standard excavation and grid installation works ✓ Compatible
Custom logo printing on request ✓ Compatible
Use as a substitute for cable locating before digging ✗ Not recommended
Projects where voltage or cable type has not been confirmed against this product ✗ Not recommended
Use near moving machinery with entanglement risk ✗ Not recommended

 

Who is this for

This board suits utility contractors, groundworkers, and electrical grid installers laying or maintaining buried electric cables who need a compliant, highly visible protection layer above the cable. It is intended for use during excavation, cable installation, and reinstatement works where a physical and visual warning barrier is required above a buried electric cable.

Typical applications

  • Laying protection boards directly above newly installed underground electric cables during grid installation works.

  • Reinstating protection above existing buried cables uncovered during excavation or repair works.

  • Providing a visible warning layer above cables running under roads, verges, and site access routes.

  • Supporting DNO and utility company site specifications requiring a physical cable protection layer.

  • Branding site materials with a utility company or contractor logo for asset identification.

How to use

Step 1: Confirm the exact cable position and depth using appropriate cable locating equipment before excavation or installation.
Step 2: Lay the protection board directly above the cable at the depth and position specified by the relevant DNO or project specification.
Step 3: Overlap adjoining boards as required to maintain continuous coverage along the length of the cable run.
Step 4: Backfill above the board following the project's reinstatement specification.
Step 5: Record the board position in site records or as-built drawings to support future excavation safety.

Common mistakes

  • Relying on the board alone instead of confirming cable position with proper locating equipment before digging.

  • Leaving gaps between boards along a cable run, reducing the continuous protection and warning coverage.

  • Installing the board at the wrong depth relative to the cable, reducing its effectiveness as an early warning layer.

  • Failing to record board position in site records, making it harder for future excavation teams to anticipate the buried cable.

  • Assuming the board is rated for a voltage or cable type it has not been confirmed to protect.

Safety

This board is a physical and visual warning layer, not a substitute for confirming cable position with proper locating equipment before excavation. Always follow the relevant DNO or utility specification for depth, overlap, and installation method. Do not assume the board is suitable for a voltage or cable type beyond what has been confirmed for the specific project.

Maintenance

No routine maintenance is required once installed underground. Inspect boards for damage before installation and avoid using any board that shows cracking or impact damage prior to laying.

Frequently Asked Questions

Q: What is this board actually protecting the cable from?
A: The board sits directly above a buried electric cable, providing a physical impact resistant layer and a bright visual warning before excavation equipment or hand tools reach the cable itself. It is designed to give diggers and site operatives an early signal that a cable is present below, reducing the risk of an accidental strike during future excavation or repair works.

Q: Does this board carry a specific certified standard?
A: The board conforms to relevant internationally recognised cable protection standards. If a project requires confirmation of a specific standard number or DNO approval reference, this should be confirmed directly with CMT Group before specifying the board for a particular contract, since requirements vary between utility companies and projects.

Q: What is this board NOT suitable for?
A: This board is not a substitute for confirming cable position and depth using proper cable locating equipment before excavation. It should not be assumed suitable for a voltage or cable type beyond what has been confirmed for the specific project, and it is not intended to replace DNO specified protection where a particular product or standard has been mandated.

Q: Why choose this over a standard unbranded protection board?
A: Most cable protection boards on the market are supplied as plain warning boards with no option to add project or company identification. This board can be custom printed with a logo, supporting utility companies and contractors who want their branding visible on site materials used across grid installation and maintenance works.

Q: How many boards are needed to cover a length of cable run?
A: Board coverage depends on the length of cable run and the overlap required by the relevant DNO or project specification. Boards should be laid with sufficient overlap to avoid gaps in protection along the cable, so the exact quantity needed should be calculated against the confirmed trench length and overlap requirement for the project.

Q: How long will this board last once installed underground?
A: The board is built from a rot resistant, chemically inert material designed for long service life in underground conditions without degrading from soil moisture or chemical exposure. Once installed correctly at the specified depth, it requires no routine maintenance for the remainder of its service life underground.