Six socket extension lead with a 2m cable for indoor home, office, and site office use where four sockets are insufficient for the number of devices being powered simultaneously.
- BS1363/A compliant, RoHS compliant
- 6 x 13A BS1363 sockets
- 13A plug, 240V
- 2m cable, indoor use only
- Maximum total load 13A (3,120W across all sockets)
- White
6 Gang Extension Lead 2m
Six socket extension lead with a 2m cable for indoor home, office, and site office use where four sockets are insufficient for the number of devices being powered simultaneously.
- BS1363/A compliant, RoHS compliant
- 6 x 13A BS1363 sockets
- 13A plug, 240V
- 2m cable, indoor use only
- Maximum total load 13A (3,120W across all sockets)
- White
- Buy 5 for £20.26 £16.88 each and save 9%
- Buy 10 for £18.10 £15.08 each and save 19%
| BULK DISCOUNT | 5 | 10 |
|---|---|---|
| Price | £16.88 £20.26 | £15.08 £18.10 |
Order 1x to earn 18 FASTPoints
Order to earn 18 FASTPoints
Log in to access trade discounts6 Gang Extension Lead - 2m
Six socket extension lead with a 2m cable, designed for indoor environments where a standard 4-gang lead provides insufficient socket capacity for the devices in use. Six 13A BS1363 sockets on a single 2m cable accommodates home entertainment setups, multi-device office desks, site office workstations, and any indoor setting where simultaneous connection of six devices is required from one mains socket. BS1363/A compliant and RoHS compliant.
How six sockets on one lead removes the need for multiple extension leads in the same space
A standard 4-gang lead falls short when a workstation, entertainment unit, or site office desk requires power for more than four devices simultaneously. The common response is to add a second extension lead, either plugging it into a spare socket or into the first lead. Connecting one extension lead into another is not permitted under IET Wiring Regulations and creates overloading and fire risks. A single 6-gang lead removes that need by providing six outlets from one mains connection, keeping the installation within the rules and removing the compliance risk of daisy-chaining.
Key Features
-
Six 13A BS1363 sockets: Six standard UK socket outlets from a single 13A mains plug. Accommodates computers, monitors, phones, chargers, and other office or home devices simultaneously without the need for a second lead. Total combined load across all six sockets must not exceed 13A (3,120W at 240V).
-
BS1363/A compliant: Meets the UK standard for 13A plugs and socket outlets. BS1363/A compliance confirms the plug and sockets are made to the current UK specification for domestic and light commercial electrical accessories.
-
2m cable: Sufficient reach for most desk, workstation, and entertainment setups where the mains socket is nearby but not directly adjacent to the equipment. Keeps the installation tidy without the excess cable of a longer lead.
-
13A UK Type G plug: Standard UK fused mains plug for connection to any domestic or commercial UK socket. Replace the fuse only with the correct 13A rated fuse if it blows.
-
RoHS compliant: Meets the Restriction of Hazardous Substances directive, confirming restricted substances are not present above permitted concentration limits.
-
Indoor use only: No IP rating is assigned to this product. It is designed and tested for dry indoor environments only and must not be used in outdoor, damp, or wet conditions.
Who is this for
Trades and roles:
-
Office managers and facilities managers
-
Site managers equipping indoor site offices
-
Home users and home workers
-
AV and entertainment setup teams
Industries:
-
Construction (indoor site offices and cabins)
-
Light commercial and retail
-
Residential and home working
-
Hospitality and events (indoor)
Specifications
| Specification | Detail |
| Product Name | 6 Gang Extension Lead 2m |
| SKU | EL24W62 |
| Sockets | 6 x 13A BS1363 |
| Plug | 13A UK Type G |
| Voltage | 240V |
| Maximum Total Load | 13A (3,120W at 240V across all sockets) |
| Cable Length | 2m |
| Standards | BS1363/A compliant |
| Environmental | RoHS compliant |
| Colour | White |
| Weight | 398g |
Compatibility
| Application or condition | Status |
| Office and home workstation power distribution | ✓ Suitable |
| Home entertainment setups requiring multiple sockets | ✓ Suitable |
| Site offices, cabins, and portable buildings (indoor) | ✓ Suitable |
| Meeting rooms, breakout areas, and light commercial | ✓ Suitable |
| Multi-device charging and connectivity stations | ✓ Suitable |
| Total load up to 13A (3,120W) across all sockets | ✓ Suitable |
| Total load exceeding 13A across all sockets | ✗ Not suitable |
| Daisy-chaining with other extension leads | ✗ Not permitted |
| Use coiled or under carpet during operation | ✗ Not suitable |
Who is this for
This extension lead is designed for home users, office teams, and site office managers who need six simultaneous socket outlets from a single mains connection in a dry indoor environment. It is the correct choice when a 4-gang lead does not provide enough sockets and adding a second lead would require daisy-chaining, which is not permitted. The 2m cable suits desk, workstation, and entertainment unit positions where the mains socket is nearby but not immediately adjacent to the equipment.
Typical applications
-
Powering a full home office setup including computer, monitor, printer, desk lamp, phone charger, and speakers from a single mains socket.
-
Providing socket capacity for home entertainment systems involving a television, games console, soundbar, streaming device, and associated charging equipment.
-
Equipping a site office or welfare cabin with power for multiple devices including computers, monitors, a kettle, and phone chargers from one mains outlet.
-
Distributing power across a retail point-of-sale workstation requiring till, card reader, receipt printer, monitor, and associated equipment.
-
Supplying a multi-device meeting room setup including display, laptop, conference speaker, and device charging from a single nearby wall socket.
-
Providing additional indoor socket capacity in a workshop or utility room where multiple low-wattage devices such as battery chargers and lighting require simultaneous power.
How to use
Step 1: Switch off the mains socket before connecting. Insert the 13A plug fully and switch on.
Step 2: Before connecting devices, add the wattage of all items to be powered simultaneously. The combined total across all six sockets must not exceed 13A (3,120W at 240V).
Step 3: Lay the cable out fully before use. Do not operate with the cable coiled or bundled.
Step 4: Keep the lead in dry indoor conditions only. This product has no IP rating and must not be used in damp, wet, or outdoor environments.
Step 5: Switch off at the mains socket when not in use.
Common mistakes
-
Overloading across six sockets: six sockets sharing one 13A fuse means the combined wattage of all six devices must stay within 3,120W. Six moderate devices can easily approach this limit, add the wattage of everything before connecting.
-
Using outdoors or in damp conditions: this lead carries no IP rating. It must be used in dry indoor environments only. For workshop or covered outdoor use, select an IP44-rated lead from the CMT range.
-
Daisy-chaining to get more sockets: connecting a second extension lead into this one is not permitted under IET Wiring Regulations. If six sockets are not sufficient, consult an electrician about additional fixed socket outlets.
-
Running the cable under a mat or carpet: a covered cable cannot ventilate during use. Keep the full cable length clear of floor coverings and obstructions.
-
Operating with the cable coiled: always extend the cable fully before use. A coiled cable under load generates heat it cannot dissipate.
Safety
This extension lead is rated for a maximum total load of 13A (3,120W at 240V) across all six sockets. It is designed for dry indoor use only and carries no IP rating. Do not use in outdoor, damp, or wet environments. Do not daisy-chain into another extension lead. Always fully extend the cable before use. Do not run under carpets, mats, or floor coverings. Replace the plug fuse only with a 13A rated fuse. BS1363/A compliant and RoHS compliant.
Maintenance
Inspect the cable, plug, and all six socket faces before each use. Remove from service if the cable is damaged, the plug casing is cracked, or any socket face is deformed or damaged. Keep socket faces free from debris. Wipe with a dry cloth only. Do not use water, solvents, or abrasive cleaners on any part of the lead. Store loosely coiled in a dry location when not in use.
Frequently Asked Questions
Q: What is the maximum total load I can run across all six sockets?
A: All six sockets share a single 13A plug and fuse, so the maximum combined load across the entire unit is 13A (3,120W at 240V). This is not 13A per socket, it is 13A for the whole lead. Before connecting devices, add the wattage printed on each item you intend to power simultaneously and confirm the total stays within this limit. Six moderate devices such as a computer, monitor, printer, and phone chargers can collectively approach this figure, so checking is worthwhile before use.
Q: Can I use this extension lead outdoors or in a workshop?
A: No. This lead carries no IP rating and is designed and tested for dry indoor environments only. Using it in outdoor conditions, damp environments, or anywhere condensation may reach the sockets or cable is outside its tested scope and creates an electrical safety risk. For workshop and covered outdoor use, the CMT range includes IP44-rated 4-gang leads in 1m, 2m, and 5m cable lengths.
Q: Why is this better than adding a second 4-gang lead?
A: Connecting a second extension lead into a 4-gang lead to get more sockets is daisy-chaining, which is prohibited under IET Wiring Regulations. It creates an overloading risk at the first lead's socket and is a recognised cause of electrical fires. A single 6-gang lead provides six outlets from one mains connection within the permitted load limit, keeping the installation compliant and safe without any secondary lead connection.
Q: What does BS1363/A compliant mean for this product?
A: BS1363 is the UK standard for 13A plugs and socket outlets, defining the physical dimensions, electrical performance, and safety requirements for the plug pins, socket shutters, and contact materials. BS1363/A is the amendment covering extension lead sockets specifically. Compliance confirms the plug and sockets on this lead meet the current UK specification for domestic and light commercial electrical accessories.
Q: Can I connect high-wattage appliances such as a kettle or electric heater?
A: Individual high-wattage appliances can be connected provided the total combined load across all six sockets does not exceed 13A (3,120W). A kettle typically draws 2,200 to 3,000W and an electric fan heater 1,000 to 3,000W, either can approach or reach the full 13A limit on their own, leaving minimal or no capacity for other connected devices. Always calculate the combined total before use.