  • 3,000W maximum heat output on high setting, 240V AC, 50Hz
  • Three settings: fan only, intermediate heat, and 3kW high heat
  • Adjustable dial thermostat with automatic temperature maintenance
  • Compact drum format with angled cradle for directed heat positioning
  • 2.2kg, highly portable between work areas
  • CE marked, WEEE compliant

MAX 240V Electric Fan Heater 3kW - Industrial

Code
ELHE0001
Out of Stock

A compact 240V industrial electric fan heater delivering up to 3kW of convection heat for workshops, garages, site offices, and indoor working areas.

  • 3,000W maximum heat output on high setting, 240V AC, 50Hz
  • Three settings: fan only, intermediate heat, and 3kW high heat
  • Adjustable dial thermostat with automatic temperature maintenance
  • Compact drum format with angled cradle for directed heat positioning
  • 2.2kg, highly portable between work areas
  • CE marked, WEEE compliant
£41.54 £34.62
  • Buy 3 for £38.28 £31.90 each and save 8%
  • Buy 6 for £35.48 £29.57 each and save 15%
  • BULK DISCOUNT 3 6
    Price £31.90 £38.28 £29.57 £35.48

Order 1x to earn 34 FASTPoints

Order to earn 34 FASTPoints

Log in to access trade discounts
Out of Stock

MAX 240V Electric Fan Heater 3kW

A compact drum-format 240V electric fan heater delivering up to 3kW of convection heat from a lightweight, portable housing weighing 2.2kg. Built for workshops, garages, site offices, and indoor commercial environments on standard 240V mains power, with a three-position mode selector, adjustable dial thermostat, and angled cradle mounting that lets you direct heat exactly where the work is happening.

How the compact drum format solves the positioning problem

A full-size cabinet or panel heater heats the air in a room broadly, useful if the room is small enough to warm efficiently, less useful in a large workshop, open-plan warehouse bay, or site office where the heat dissipates before reaching the operative. The drum format of this heater is designed to be directed. The angled cradle lets you position the outlet precisely, at desk height, toward a specific workstation, or angled down into a working pit. At 2.2kg, you can move it from bench to bench, carry it between rooms, or set it up in a welfare unit at the start of a shift and move it to the workshop floor in the afternoon. That level of flexibility is what separates a genuinely portable work heater from one that just sits in the corner.

Key Features

  • 3kW convection heat output: Maximum output of 3,000W on the high heat setting warms a working area quickly on a standard 240V mains supply. The intermediate setting provides a lower heat level, and the fan-only mode circulates air without heat for summer ventilation or maintaining air movement in enclosed spaces.

  • Adjustable dial thermostat: Set the thermostat dial to the desired temperature level. Once the room or working area reaches that temperature, the thermostat maintains it automatically by cycling the heating element on and off. The fan continues to run throughout.

  • Compact drum format with angled cradle: The circular drum housing sits in a fixed-angle floor cradle that positions the heat outlet at a practical working angle. At 250 x 225 x 300mm, the heater takes up minimal floor space and can be positioned on a workbench or floor.

  • Fan-only mode: Operates the fan without activating the heating element, useful for air circulation, cooling down a warm space, or maintaining airflow in enclosed working areas.

  • Lightweight and portable: At approximately 2.2kg, this is a genuinely portable unit. One-handed carry between areas, no trolley or assistance required.

  • CE marked: CE marked and WEEE compliant.

Who Is This For

Trades and roles:

  • Workshop and garage operatives

  • Site office and welfare unit users

  • General construction operatives

  • Maintenance and facilities teams

  • Light commercial and industrial workers

Industries:

  • Construction and site welfare

  • Automotive workshops and garages

  • Light industrial and manufacturing

  • Commercial offices and retail

  • Facilities management and building maintenance

 Specifications

Specification Detail
Product name MAX 240V Electric Fan Heater 3kW - Industrial
SKU ELHE0001
Brand MAX
Product type Industrial electric fan heater
Supply voltage 240V AC
Frequency 50Hz
Power, high heat 3,000W
Power, low/fan 30W
Heating settings 3: fan only, intermediate heat, high heat (3,000W)
Thermostat Adjustable dial thermostat with automatic temperature maintenance
Housing Compact drum format with angled floor cradle
Certifications CE marked, WEEE compliant
Dimensions D 250 x W 225 x H 300mm
Weight 2.2kg approx.

Compatibility

Application or condition Status
Workshops and garages on 240V mains supply ✓ Suitable
Site offices and welfare units ✓ Suitable
Indoor commercial and light industrial spaces ✓ Suitable
Supplementary or localised heating in larger spaces ✓ Suitable
Fan-only air circulation without heat ✓ Suitable
Primary or sole heat source for large buildings ✗ Not suitable per manufacturer guidance
Near flammable liquids, gases, or compressed gas cylinders ✗ Not suitable
Bathrooms, near water, or damp floors ✗ Not suitable
Use with programmable timer for automatic switch-on ✗ Not suitable
Outdoor use ✗ Not suitable

 

Who Is This For

This heater is used primarily by workshop operatives, garage owners, and site welfare managers who need fast, directed convection heat in a compact indoor space on a standard 240V mains supply. It works well as a supplementary heater in larger spaces where the building's central heating is insufficient for a specific working area, and equally well as the primary heat source in smaller enclosed spaces such as site offices, store rooms, and welfare cabins. The 2.2kg weight and compact drum format make it a practical choice for anyone who needs to move a heater between rooms or working areas during the day without assistance.

Typical Applications

  • Heating a workshop or garage bay during cold weather, directed at the working area rather than attempting to warm the full building volume.

  • Providing supplementary heat at a specific workstation in a warehouse or light industrial unit where the general building heating does not reach the required level.

  • Warming a site office, welfare cabin, or temporary accommodation at the start of a shift on a standard 240V site supply.

  • Directed heat at a damp or cold corner of a room to assist with drying or to bring a working area up to a usable temperature quickly.

  • Fan-only air circulation in a warm enclosed space during summer months where air movement is needed without additional heat.

How to Use

Step 1: Place the heater on a firm, level surface in its upright position. Maintain a minimum 1 metre clearance all around from any flammable materials, curtains, or combustible objects.

Step 2: Connect the plug to a suitable 240V mains supply. Ensure the supply is rated to handle the 3kW draw on the high heat setting.

Step 3: Set the thermostat dial to the maximum position (fully clockwise) before selecting a heat mode, to allow the heater to reach the working temperature without cutting out prematurely.

Step 4: Set the mode selector to the desired setting: fan only, intermediate heat, or high heat. The heater takes up to three minutes to reach optimum output on the heating settings.

Step 5: Once the space reaches the required temperature, turn the thermostat dial slowly anticlockwise until you hear the thermostat click. Leave the dial in that position. The thermostat maintains the temperature automatically from that point by cycling the element on and off.

Step 6: When finished, turn the mode selector to off before disconnecting from the mains. Allow the heater to cool before storing.

Common Mistakes

  • Setting the thermostat too low before reaching temperature: the thermostat cuts out the heating element when it reaches the set level. If the dial is set too low at the start, the element cuts off before the room has warmed, and the heater runs on fan only. Set the thermostat to maximum on start-up, then dial back once the room is up to temperature.

  • Placing on a deep pile carpet: the air intake at the base of the heater draws air from beneath the unit. A deep pile carpet can partially block this intake, restricting airflow and causing the unit to overheat. Use on a hard floor or a low-pile surface.

  • Using with an automatic timer: the manufacturer specifically advises against using this heater with a programmable timer set to switch it on automatically. The heater may be covered or positioned incorrectly when the timer activates.

  • Leaving unattended while in operation: turn off and unplug whenever leaving the area for an extended period.

  • Blocking the air outlet: never cover any part of the heater. The outlet must remain clear during operation.

Safety

This is a Class I earthed appliance, the plug must be correctly connected to an earthed supply. Keep a minimum of 1 metre clearance between the air outlet and any textiles, curtains, or flammable materials. Do not use near flammable liquids, gases, or compressed gas cylinders. Do not use in bathrooms, near water, or on a damp floor. Do not insert any objects through the outlet grilles or air intake grilles. The heating surfaces become very hot during operation, keep children and vulnerable people away from the unit while it is in use. If the heater is dropped or shows any visible damage, do not use it. A slight emission of smoke on first use is normal and stops after a short time, this is caused by the protective oil coating on the heating element burning off.

Maintenance

Clean the heater body with a soft, damp cloth. Do not use solvents or abrasive materials. Keep the inlet and outlet grilles clear of dust and debris, he most common cause of overheating is dust accumulation on the heating element. To clean the grilles, allow the heater to cool completely, disconnect from the mains supply, and clean the grilles with a vacuum cleaner. Do not attempt any internal maintenance, there are no user-serviceable parts inside the heater. Any internal repairs must be carried out by a qualified technician. Store in a safe, dry, child-proof location when not in use.

Frequently Asked Questions

Q: What are the three heat settings and how do I use them?
A: The mode selector has three positions: fan only, intermediate heat, and high heat at 3,000W. Fan only runs the motor without activating the heating element, useful for air circulation without warmth. Intermediate heat provides a lower heat output for milder conditions or smaller spaces. High heat delivers the full 3,000W output for rapid warming of a working area. The thermostat dial works alongside the mode selector to maintain the temperature automatically once the desired level is reached.

Q: What is this heater NOT suitable for?
A: This heater is not suitable as the sole heat source for large buildings or open industrial spaces, the manufacturer's guidance describes it as supplementary or localised heating, not a primary heating system. It must not be used near flammable liquids, gases, or compressed gas cylinders, or in bathrooms, near water, or on a damp floor. It must not be used with a programmable timer for automatic switch-on. It is for indoor use only and must not be used outdoors.

Q: What is the difference between this fan heater and an infrared cabinet heater?
A: A fan heater warms the air in a room by drawing cold air over a heating element and blowing warm air out, the room warms gradually as the air temperature rises. An infrared heater warms objects and people directly in front of it without heating the air in between. Fan heaters warm a sealed room more evenly; infrared heaters deliver instant localised warmth regardless of draughts. For small enclosed spaces, a fan heater is often more practical. For large, draughty, or partially open environments, infrared is more efficient.

Q: Why is there a slight smell or smoke when first switching the heater on?
A: A brief emission of smoke or a slight smell on first use is normal. The heating element is coated with a protective oil during manufacture, and this burns off the first time the element reaches operating temperature. It stops after a short period and does not recur. If smoke or burning smell persists beyond the first use, switch off immediately, disconnect from the mains, and do not use the heater again until it has been inspected by a qualified technician.

Q: Can this heater be used in a dusty environment?
A: With care, yes, but regular maintenance is essential. Dust accumulating on the heating element is the most common cause of overheating. In dusty environments, the grilles should be cleaned more frequently using a vacuum cleaner after disconnecting and allowing the heater to cool fully. Do not use the heater if the grilles are visibly blocked.

Q: How do I get the thermostat to maintain a steady temperature?
A: Set the mode selector to a heat setting and the thermostat dial to maximum to bring the room up to temperature. Once the room reaches the level you want, slowly turn the thermostat dial anticlockwise until you hear a click, this is the thermostat cutting the element off at the current temperature. Leave the dial at that position. The thermostat will cycle the element on and off to maintain that temperature automatically.