Inherent FR hi-vis trousers front view with two retroreflective bands on each leg | CMT Group UK
Inherent FR hi-vis trousers front view with two retroreflective bands on each leg | CMT Group UK Hi-vis yellow flame retardant arc flash cargo trousers three-quarter view with kneepad pockets | CMT Group UK Yellow arc flash work trousers back view with flapped rear pockets and belt loops | CMT Group UK

Hi-vis yellow inherent flame retardant arc flash cargo trousers for electrical, utility and roadside workers needing arc, flame and visibility protection.

  • Inherent flame retardant rip stop fabric
  • Arc rated - ELIM 9.5 cal/cm2, ATPV 10 cal/cm2, APC 1
  • EN ISO 20471 Class 2 hi-vis (smaller sizes Class 1)
  • Anti-static to EN 1149
  • EN ISO 11612, EN ISO 11611 Class 1, EN 13034
  • Top-loading kneepad pockets
  • Available in multiple sizes

MAXFR Hi-Vis Yellow Inherent Flame Retardant Arc Flash Cargo Trousers

Code
CL010007
In stock

Hi-vis yellow inherent flame retardant arc flash cargo trousers for electrical, utility and roadside workers needing arc, flame and visibility protection.

  • Inherent flame retardant rip stop fabric
  • Arc rated - ELIM 9.5 cal/cm2, ATPV 10 cal/cm2, APC 1
  • EN ISO 20471 Class 2 hi-vis (smaller sizes Class 1)
  • Anti-static to EN 1149
  • EN ISO 11612, EN ISO 11611 Class 1, EN 13034
  • Top-loading kneepad pockets
  • Available in multiple sizes
Grouped product items
28" Regular Code CL010007-28R
£113.57 £94.64
Bulk Discounts
30" Regular Code CL010007-30R
£113.57 £94.64
Bulk Discounts
32" Regular Code CL010007-32R
£113.57 £94.64
Bulk Discounts
34" Regular Code CL010007-34R
£113.57 £94.64
Bulk Discounts
36" Regular Code CL010007-36R
£113.57 £94.64
Bulk Discounts
38" Regular Code CL010007-38R
£113.57 £94.64
Bulk Discounts
40" Regular Code CL010007-40R
£113.57 £94.64
Bulk Discounts

MAXFR Hi-Vis Yellow Inherent Flame Retardant Arc Flash Cargo Trouser

Hi-vis yellow inherent flame retardant arc flash cargo trousers protect against arc flash, flame and heat while keeping the wearer visible. They are made from lightweight inherent FR rip stop fabric, so the flame resistance is part of the fibre rather than a surface finish. Electrical, utility and roadside teams wear them where one pair of trousers must cover arc, flame, static and visibility risks.

How Top-Loading Kneepad Pockets Keep Kneepads in Place

On many work trousers the kneepads load from the bottom, so they slide out or drop down when the wearer kneels and stands. On site, that leaves the knee unprotected and means stopping to refit the pad. These trousers have external top-loading kneepad pockets, so kneepads go in from the top and stay where they should.

Key Features

  • Inherent flame retardant fabric: the flame resistance is part of the fibre, not a finish applied to the surface.

  • Arc rated with APC 1: ELIM 9.5 cal/cm2 and ATPV 10 cal/cm2 in open arc testing.

  • Anti-static to EN 1149: dissipates static charge when the wearer is earthed, reducing the risk of a spark.

  • Hi-vis yellow with retroreflective tape: two bands on each leg for visibility in low light and at the roadside.

  • External top-loading kneepad pockets: kneepads go in from the top and do not slide out when kneeling.

  • Triple stitching in aramid thread: high strength seams with a bar-tacked crotch panel for hard daily wear.

  • Comfort side waist elastication: moves with the wearer, with a large rear belt loop for a work belt.

Who is this for

Trades and roles

  • Electricians

  • Cable jointers

  • Overhead line engineers

  • Substation engineers

  • Highways maintenance operatives

  • Utility engineers

  • Maintenance engineers

Industries

  • Electricity transmission and distribution

  • Utilities

  • Highways and street works

  • Power generation

  • Petrochemical and process

  • Infrastructure maintenance

 Specifications

Specification Detail
Product name MAXFR Hi-Vis Yellow Inherent Flame Retardant Arc Flash Cargo Trousers
Product code CL010007
Garment type Cargo trousers
Protection Flame retardant, anti-static, electric arc, high visibility, welding, limited chemical splash
Open arc test (EN 61482-1-1) ELIM 9.5 cal/cm2, ATPV 10 cal/cm2
Box test (EN 61482-1-2) APC 1 (4 kA)
Heat and flame EN ISO 11612, A1, A2, B1, C1, F1
High visibility EN ISO 20471, Class 2 (smaller sizes Class 1)
Welding EN ISO 11611, Class 1
Chemical splash EN 13034, limited protection against liquid chemicals
Electrostatic EN 1149, anti-static
Fabric Inherent flame retardant rip stop
Stitching Aramid high strength thread, triple stitched
Crotch Crotch panel with bar tack
Waist Comfort side elastication, large rear belt loop
Fly Plastic zip
Pockets 2 cargo pockets, 2 rear pockets, 2 external top-loading kneepad pockets
Reflective tape Retroreflective tape, 2 bands on each leg
Brand MAXFR
Colour Hi-vis yellow
Sizes 28R to 40R

Size Selection

Product code Size To fit waist
CL010007-28R 28 Regular 71.1 cm (28 in)
CL010007-30R 30 Regular 76.2 cm (30 in)
CL010007-32R 32 Regular 81.3 cm (32 in)
CL010007-34R 34 Regular 86.4 cm (34 in)
CL010007-36R 36 Regular 91.4 cm (36 in)
CL010007-38R 38 Regular 96.5 cm (38 in)
CL010007-40R 40 Regular 102 cm (40 in)

Other Sizes in the Range, Contact Our Team to Order

Size To fit waist
28 to 56 Short 71.1 to 142.2 cm (28 to 56 in)
42 to 56 Regular 106.7 to 142.2 cm (42 to 56 in)
28 to 56 Tall 71.1 to 142.2 cm (28 to 56 in)

Compatibility

Base material, tool or condition Suitability
Assessed arc risk up to 9.5 cal/cm2 and APC 1 Suitable as part of a full arc-rated outfit
Arc risk above 9.5 cal/cm2 or requiring APC 2 Not recommended, use clothing rated for the assessed incident energy
Roadside and low-light work Suitable, Class 2 hi-vis with retroreflective tape (smaller sizes Class 1)
Full-body Class 3 requirement Suitable when worn with a Class 3 hi-vis upper garment
Work on or near the railway Not recommended, rail sites require orange to RIS-3279-TOM
Lower-risk welding and allied processes Suitable, EN ISO 11611 Class 1
Heavy welding with high spatter Not recommended, use Class 2 welding clothing
Light splashes of liquid chemicals Suitable for limited protection to EN 13034
Heavy chemical exposure or immersion Not recommended, use chemical protective clothing
Areas where static build-up must be controlled Suitable with an anti-static upper garment and anti-static footwear
Kneeling work Suitable with kneepads fitted in the kneepad pockets
Firefighting Not recommended, this is industrial heat and flame clothing

 

Typical Users and Projects

Network, utility and highways teams wear these trousers for outdoor electrical work where they must also be seen. They suit cable jointing in the street, substation work and overhead line maintenance, often in low light. Wearers are usually trained operatives working under an arc flash risk assessment and site PPE rules.

Typical applications

  • Cable jointing in excavations at the roadside, kneeling with kneepads fitted.

  • Switching and inspection work in substations where an arc risk has been assessed.

  • Overhead line and street lighting maintenance in low light.

  • Utility network repairs on highways and in street works.

  • Maintenance on process sites where flame, static and splash risks must be controlled.

  • Light welding and cutting tasks during maintenance work.

How to use

Step 1: Check that the incident energy in your arc flash risk assessment is within the trousers’ ELIM of 9.5 cal/cm2.
Step 2: Choose the size by waist measurement using the Size Selection table.
Step 3: Wear an FR or natural-fibre base layer underneath, never polyester or nylon.
Step 4: Fit kneepads from the top into the kneepad pockets before kneeling work.
Step 5: Wear a Class 3 hi-vis FR upper garment where full-body Class 3 visibility is required.
Step 6: Add arc-rated gloves, face protection and anti-static footwear as your risk assessment requires.
Step 7: Check the trousers before each shift for holes, worn seams, contamination or damaged reflective tape.

Common mistakes

  • Wearing them on rail sites, where orange to RIS-3279-TOM is required.

  • Assuming every size is Class 2, when smaller sizes are certified to Class 1.

  • Wearing non-FR thermal leggings underneath in cold weather.

  • Kneeling without kneepads fitted in the kneepad pockets.

  • Wearing them when soiled with oil or grease, which can reduce protection.

Safety

Isolation comes first. The Electricity at Work Regulations 1989 only allow live work where it is unreasonable to make equipment dead. Choose the outfit from a documented arc flash risk assessment. For roadside work, follow the hi-vis requirements of the site or the principal contractor.

Maintenance

Wash and dry following the care label on the garment, separately from ordinary clothing. Store clean and dry. Replace the trousers if they have holes, burns, contamination that will not wash out, or faded fabric and cracked reflective tape.

Frequently Asked Questions

Q: What arc rating do these trousers have?
A: In open arc testing to EN 61482-1-1 they have an ELIM of 9.5 cal/cm2 and an ATPV of 10 cal/cm2. ELIM is the incident energy at which no second-degree burn is predicted, while ATPV is the point at which there is a 50% chance of one. In the box test to EN 61482-1-2 they reach APC 1, tested at 4 kA. Use the ELIM when matching them to your risk assessment.

Q: What does 32R mean on these trousers?
A: The 32 is the to-fit waist in inches, which is 81.3 cm. The R stands for Regular leg length. Measure your waist where you wear your trousers and choose the size that matches.

Q: What do A1, A2, B1, C1 and F1 mean under EN ISO 11612?
A: A1 and A2 mean the fabric limits flame spread when a flame touches its surface (A1) and its edge (A2). B1 is protection against convective heat, such as hot gases, at level 1. C1 is protection against radiant heat at level 1. F1 is protection against contact heat at level 1.

Q: Are all sizes Class 2 hi-vis?
A: The trousers are certified to EN ISO 20471 Class 2, but the smaller sizes are certified to Class 1. Smaller garments have less fluorescent fabric and tape, which sets the class. Check the class on the garment label if your site requires Class 2 legwear.

Q: What are these trousers not suitable for?
A: They are not suitable for rail sites that require orange to RIS-3279-TOM. They are not for heavy welding, heavy chemical exposure or firefighting. They are not suitable where the assessed arc incident energy is above 9.5 cal/cm2 or calls for APC 2.

Q: How are these different from the navy version?
A: Both are inherent flame retardant arc flash cargo trousers with the same arc ratings. The hi-vis yellow version adds EN ISO 20471 certification and retroreflective tape for roadside and low-light work. The navy version suits substations and plant rooms where hi-vis is not required.

Q: How do I get full-body Class 3 visibility?
A: Wear the trousers with a Class 3 hi-vis upper garment, such as a jacket or sweatshirt. Under EN ISO 20471, the combined outfit can then meet Class 3. Make sure the upper garment is also flame retardant and arc rated.

CMT Equipment Ltd