White portable oil filled radiator 2kW 9 fin front view showing power switches and thermostat control | CMT Group UK
White portable oil filled radiator 2kW 9 fin front view showing power switches and thermostat control | CMT Group UK Portable oil filled radiator 9 fin side profile showing full fin array and castor wheel base | CMT Group UK Oil filled radiator 2kW front narrow view showing white finish and four-castor freestanding base | CMT Group UK

A portable oil filled radiator providing silent, fume-free heat for site offices, welfare cabins, and portakabins on standard 240V mains supply.

  • Silent radiant heat, no fan noise or airborne dust
  • 9 fins, 2000W maximum heat output
  • 3 heat settings, adjustable mechanical thermostat
  • Overheat protection with automatic shut-off
  • Castor wheels and integrated carry handle
  • CE marked, 220-240V AC mains connection

 

240V Portable Oil Filled Radiator 2kW - Site Office and Welfare Cabin

Code
SOFR20
10+ In Stock

A portable oil filled radiator providing silent, fume-free heat for site offices, welfare cabins, and portakabins on standard 240V mains supply.

  • Silent radiant heat, no fan noise or airborne dust
  • 9 fins, 2000W maximum heat output
  • 3 heat settings, adjustable mechanical thermostat
  • Overheat protection with automatic shut-off
  • Castor wheels and integrated carry handle
  • CE marked, 220-240V AC mains connection

 

£154.80 £129.00
  • Buy 3 for £142.80 £119.00 each and save 8%
  • Buy 6 for £130.80 £109.00 each and save 16%
  • BULK DISCOUNT 3 6
    Price £119.00 £142.80 £109.00 £130.80

Order 1x to earn 129 FASTPoints

Order to earn 129 FASTPoints

Log in to access trade discounts
10+ In Stock

240V Portable Oil Filled Radiator 2kW

Oil filled radiators provide silent, fume-free heat for enclosed site spaces where fan heaters are unsuitable and propane or diesel heaters introduce combustion risk. This portable radiator connects to a standard 240V mains socket, operates without fan noise or airborne particulates, and maintains a set temperature automatically through its adjustable mechanical thermostat. Suited to welfare cabins, portakabins, site offices, drying rooms, and security cabins where consistent background heat is needed throughout a working day.

Why oil-filled heating outperforms fan heaters in enclosed site spaces

Fan heaters in welfare cabins and site offices push air continuously across the space, which produces a localised blast of warmth near the unit whilst corners stay cold and the fan noise makes rest periods uncomfortable. Workers tend to switch them up to maximum output for entire shifts rather than letting them cycle, which means higher running costs and uneven results. An oil filled radiator heats sealed thermal oil inside the fins, which then radiates warmth slowly and evenly across the room. The oil retains heat after the thermostat cycles off, so the space stays warm without the element drawing continuous power, and there is no circulated air, no dust, and no noise.

Key Features

  • Silent radiant operation: No fan, no moving parts, no circulated air or dust. Operatives in welfare cabins and site offices can rest during meal breaks without fan noise or air movement.

  • 3 heat settings, 2000W maximum output: Three switch-selectable output levels allow the heater to be matched to the space size and the day's ambient temperature, avoiding full-power draw in mild conditions.

  • Adjustable mechanical thermostat: Once the target temperature is reached, the thermostat cycles the element on and off automatically to hold that temperature without manual adjustment throughout the day.

  • Overheat protection: An integrated thermal cut-off shuts the unit down automatically if internal temperature exceeds safe limits, including if airflow around the fins becomes obstructed.

  • Castor wheels and carry handle: Four castors allow repositioning across a welfare facility without lifting. The carry handle allows safe two-person transport between locations on site.

  • Integrated cord storage: The cable stows on the unit when not in use, reducing trip hazard risk during storage and transit between site locations.

  • Sealed oil system, no maintenance required: The oil reservoir is factory-sealed. No refilling, no top-ups, and no servicing under normal operating conditions.

Who is this for

Trades and roles:

  • Site managers

  • Welfare facilities managers

  • Facilities coordinators

  • Site supervisors

  • Security and gatehouse personnel

Industries:

  • Construction

  • Civil engineering

  • Utilities

  • Facilities management

  • Events and temporary structures

 Specifications

Specification Detail
roduct Name 240V Portable Oil Filled Radiator 2kW - Site Office and Welfare Cabin
SKU SOFR20
Product Type Portable freestanding oil filled radiator
Rated Power 2000W (2kW)
Voltage 220-240V AC
Frequency 50/60Hz
Heat Settings 3 settings: low, medium, 2000W maximum
Thermostat Adjustable mechanical thermostat
Number of Fins 9
Safety Features Overheat protection with automatic shut-off
Mobility 4 castor wheels, integrated carry handle
Cord Management Integrated cord storage
Mains Plug UK Type G (BS 1363)
Setup Required Castor feet attachment before first use
Certification CE marked
Compliance WEEE registered
Use Environment Indoor use only
Colour White

Compatibility

Application or condition Status
Site welfare cabins and rest facilities ✓ Suitable
Modular site offices and portakabins ✓ Suitable
Site canteens and meal break areas ✓ Suitable
Security and gatehouse cabins ✓ Suitable
Drying rooms for PPE and workwear ✓ Suitable
Domestic rooms and small home offices ✓ Suitable
Enclosed spaces up to approx. 20m² ✓ Suitable
Outdoor use ✗ Not suitable
Wet or damp environments ✗ Not suitable
Areas with flammable liquids or gases ✗ Not suitable
Use with extension lead or external timer ✗ Not suitable
Large, open, or poorly insulated spaces ✗ Not suitable
Primary heat for large welfare complexes ✗ Not suitable

 

Who is this for

The portable oil filled radiator is used primarily by site managers, welfare facilities managers, and facilities coordinators equipping welfare cabins, portakabins, and temporary site offices with background electric heating during autumn and winter construction projects. It is suited to any enclosed, dry, mains-connected site space where a clean, silent, and low-maintenance heat source is required for operatives during rest breaks, meal periods, or extended working days. Security and gatehouse personnel maintaining overnight or weekend presence in site entrance cabins are a further key user group, where consistent background heat is needed without requiring active management.

Typical applications

  • Providing background heating in site welfare cabins and rest facilities on construction sites during cold weather months, where operatives take meal breaks and rest periods throughout the working day.

  • Heating portakabin site offices for site managers, engineers, and commercial teams during extended on-site working periods without access to a fixed central heating system.

  • Supplying consistent background heat to drying rooms on construction sites, where operatives hang wet workwear and PPE at the end of a shift to dry overnight.

  • Heating security and gatehouse cabins at construction site entrances where personnel maintain overnight or weekend presence in an unstaffed or minimally staffed enclosure.

  • Supplementing heating in temporary event structures and modular accommodation units on mains power where a portable, plug-in heat source is required.

  • Maintaining ambient temperature in site canteens and mess facilities during scheduled meal and rest breaks in cold weather conditions.

  • Providing background heat in small domestic rooms, home offices, and utility spaces as a supplementary or backup heat source during periods when central heating is insufficient or unavailable.

How to use

Step 1: Attach the castor feet before first use. Lay the radiator body upside-down on a stable, scratch-free surface. Fit the castor mounting plates using the U-bolts and wing nuts supplied. Do not overtighten, excess torque on the wing nuts may crack the fin flanges.

Step 2: Set all switches to the OFF position before inserting the mains plug into a 240V wall socket. Do not use an extension lead.

Step 3: Rotate the thermostat knob fully clockwise to the maximum position before switching on.

Step 4: Select the required heat output using the two power switches. Switch I alone gives the low setting. Switch II alone gives the medium setting. Both switches together give the maximum 2000W output.

Step 5: Once the space reaches the target temperature, rotate the thermostat counter-clockwise slowly until the power indicator light goes out. Leave the thermostat at this position. The unit will cycle on and off automatically from this point to hold the room at that temperature.

Step 6: To adjust the set temperature, rotate the thermostat clockwise to raise or counter-clockwise to lower.

Step 7: Set all switches to OFF and remove the plug from the wall socket before leaving the space unattended for an extended period.

Common mistakes

  • Covering the unit to dry workwear: Placing PPE, wet clothing, or any material directly over the radiator fins blocks heat dissipation and triggers the overheat protection system. Dry workwear at distance from the unit, not on it.
  • Using an extension lead: At maximum output the unit draws 2000W. Most extension leads cannot safely carry this load, creating a risk of cable overheating at the socket. Always plug directly into a mains wall socket.
  • Operating on an uneven surface: The unit must stand flat on a horizontal surface. Use on inclined or uneven flooring risks instability during operation.
  • Positioning directly below a mains socket: The unit must not be placed immediately beneath an electrical socket outlet. Position it away from the socket with the cable running clear of traffic areas.
  • Failing to observe the 1 metre clearance rule: Combustible materials including workwear, paper, furniture, and curtains must be kept at least 1 metre from the front of the unit, and clear of the sides and rear. This is a fire safety requirement, not a suggestion.
  • Attempting to service the oil system: The oil reservoir is sealed and contains no user-serviceable parts. If an oil leak is visible, take the unit out of service immediately and contact a qualified service agent.

Safety

The oil filled radiator is designed for indoor use on standard 240V mains supply only. It must not be used outdoors, in wet or damp environments, or in any area where flammable liquids, gases, or vapours are stored or used. Do not operate with extension leads, external timers, or remote control systems. The integrated overheat protection shuts the unit off automatically if internal temperatures exceed safe limits. Always operate the unit upright with castor feet fitted. Maintain a minimum clearance of 1 metre from combustible materials at the front of the unit, and clear of the sides and rear. The mains cord must not be run under carpets, rugs, or any covering, and must be routed away from traffic areas. If the cord shows any sign of damage, the unit must not be used, cord replacement must be carried out by a qualified service agent only.

Maintenance

Unplug from the mains socket and allow the unit to cool fully before cleaning. Wipe exterior surfaces with a soft, slightly damp cloth. Do not use detergents, solvents, or abrasive cleaning products. Do not immerse in water or direct water at the unit. The oil system is sealed and requires no maintenance under normal operating conditions. If an oil leak is observed, take the unit out of service immediately and contact a qualified service agent. At end of life, dispose of in accordance with WEEE regulations. Do not mix with general waste. Contact your local authority for guidance on the disposal of oil-containing electrical equipment.

Frequently Asked Questions

Q: How does an oil filled radiator heat a space differently from a fan heater?
A: A fan heater uses a heating element and a fan to push warm air across the room, which produces fast results near the unit but creates noise, circulates dust, and gives uneven coverage. An oil filled radiator heats sealed thermal oil inside the fins, which radiates warmth evenly across the space without any moving parts. Because the oil holds heat after the thermostat cycles the element off, the room stays warm without the element drawing continuous power. For welfare cabins and site offices where workers are resting or eating, the absence of fan noise and circulated air is a practical benefit as much as a comfort one.

Q: What size space can this radiator heat effectively?
A: At 2kW maximum output, this unit is suited to small to medium enclosed spaces that are reasonably well insulated. In practice, a standard welfare cabin or portakabin up to approximately 15 to 20 square metres is within its effective range. In poorly insulated spaces, large rooms, or areas with significant heat loss through gaps, thin walls, or regularly opened doors, a single 2kW unit may not maintain comfortable ambient temperature without supplementary heating.

Q: What is this radiator not suitable for?
A: This unit is designed for indoor use in dry, enclosed spaces on 240V mains supply. It must not be used outdoors, in wet or damp environments including bathrooms, shower facilities, or any area exposed to water ingress. It is not suitable for areas where flammable liquids, gases, or vapours are present, or for use with extension leads, external timers, or remote control systems. It will not provide adequate heating for large, open, or poorly insulated spaces, and is not a substitute for a commercial industrial heating system in high-volume welfare facilities.

Q: How does the mechanical thermostat maintain temperature automatically?
A: Set the thermostat to its maximum position when starting the unit, then dial it back counter-clockwise once the space reaches the target temperature. The indicator light will go out at the point where the thermostat registers that temperature as the set point. From that moment, the unit cycles the heating element on and off automatically to hold the room at that level. This is the most energy-efficient operating mode, as the element only draws power when the room drops below the set temperature rather than running continuously.

Q: Can this radiator be left running in a site cabin overnight?
A: The overheat protection system provides an automatic thermal cut-off if internal temperatures reach unsafe levels, which offers a meaningful safety layer for unattended use. That said, the manufacturer advises unplugging the unit when not in active use for extended periods. For overnight operation, ensure all combustible materials are at least 1 metre clear of the unit, the surface beneath is flat and stable, and the mains cord is in sound condition with no visible damage.

Q: How does the overheat protection system work and when does it activate?
A: The overheat protection is a built-in thermal cut-off that monitors internal temperature continuously. If any part of the radiator reaches a temperature above safe operating limits, including situations where airflow around the fins is restricted, the system shuts the unit off without requiring manual intervention. The unit can be restarted once it has cooled and the cause of the obstruction has been removed. This system is a secondary safety measure and does not replace correct positioning and the 1 metre clearance requirement.

Q: Can the oil be topped up or replaced if the unit develops a fault?
A: No. The oil system is completely sealed at the factory and contains no user-serviceable parts. The oil level is set during manufacture and must not be adjusted. If an oil leak becomes visible at any point during operation or storage, take the unit out of service immediately and contact a qualified service agent. Attempting to open the oil container creates a serious safety hazard and will void any applicable warranty.

CMT Equipment Ltd