25m cable reel 240V blue drum four 13A sockets thermal cutout neon indicator front view | CMT Group UK
25m cable reel 240V blue drum four 13A sockets thermal cutout neon indicator front view | CMT Group UK Cable reel 25m rear view blue polypropylene drum iron frame stable base carry handle | CMT Group UK 25m cable reel side view blue 25m PVC cable wound on drum and 13A plug visible | CMT Group UK

25m cable reel providing four 13A sockets at 240V for indoor construction sites, workshops, and large indoor spaces where extended cable reach from a mains socket is required.

  • BS EN 61242 certified, CE and UKCA marked
  • RoHS compliant, Class I
  • 4 x 13A BS1363 sockets, 13A plug, 240V
  • Thermal cutout with neon indicator and manual reset
  • Maximum 13A (3,120W) with cable fully unwound
  • Maximum 4A (960W) with cable wound on drum
  • 1.25mm 3 core PVC cable, 25m
  • IP20, indoor and dry conditions only
  • Iron frame, polypropylene reel
  • 3.5kg

25m Cable Reel 240V - 4 Socket Thermal Cutout

Code
EL225
10+ In Stock

25m cable reel providing four 13A sockets at 240V for indoor construction sites, workshops, and large indoor spaces where extended cable reach from a mains socket is required.

  • BS EN 61242 certified, CE and UKCA marked
  • RoHS compliant, Class I
  • 4 x 13A BS1363 sockets, 13A plug, 240V
  • Thermal cutout with neon indicator and manual reset
  • Maximum 13A (3,120W) with cable fully unwound
  • Maximum 4A (960W) with cable wound on drum
  • 1.25mm 3 core PVC cable, 25m
  • IP20, indoor and dry conditions only
  • Iron frame, polypropylene reel
  • 3.5kg
£70.51 £58.76
  • Buy 5 for £66.31 £55.26 each and save 6%
  • Buy 10 for £60.24 £50.20 each and save 15%
  • BULK DISCOUNT 5 10
    Price £55.26 £66.31 £50.20 £60.24

Order 1x to earn 58 FASTPoints

Order to earn 58 FASTPoints

Log in to access trade discounts
10+ In Stock

25m Cable Reel 240V - 4 Socket 

25m cable reel providing four 13A sockets from a 240V mains supply, built for construction sites, workshops, and large indoor environments where 25 metres of cable reach from the power source is required. Certified to BS EN 61242, CE and UKCA marked, with a thermal cutout that automatically disconnects the circuit if the reel overheats from use under load whilst the cable remains wound on the drum. Maximum current when the cable is fully unwound is 13A (3,120W). Maximum current when any cable remains wound is 4A (960W). For indoor and dry use only.

How the thermal cutout prevents the most common cable reel safety failure

The most frequent cause of cable reel overheating on site is running high-wattage tools or equipment while the cable is still partially or fully wound on the drum. A wound cable cannot dissipate the heat generated by current flowing through the conductors, and the close proximity of adjacent turns means heat builds up faster than it can escape. At 13A load with the cable wound, a reel without protection will overheat within minutes. The thermal cutout on this reel monitors internal temperature and disconnects the circuit automatically when the threshold is exceeded, preventing the heat build-up from progressing to cable damage or fire. Once the reel has cooled fully, the manual reset button restores the circuit.

Key Features

  • Thermal cutout with neon indicator and manual reset: Automatically disconnects the circuit when the reel overheats. The neon indicator confirms the reel is live during use and goes off when the cutout trips. Reel must cool fully before pressing the manual reset. This is the primary safety mechanism for use when the cable cannot be fully unwound.

  • 13A unwound / 4A wound current limits: When the cable is fully extended from the drum, maximum load is 13A (3,120W) across all four sockets. When any cable remains on the drum, maximum load is 4A (960W). These limits are determined by the cable's ability to dissipate heat and must be observed regardless of the thermal cutout's presence.

  • BS EN 61242 certified, CE and UKCA marked: Certified to the UK and European standard for cable reels for household and similar purposes. CE and UKCA marking confirm independent assessment against the standard's safety requirements. Class I construction provides earth fault protection via the earth conductor in the 3 core cable.

  • 4 x 13A BS1363 sockets: Four standard UK 13A socket outlets for simultaneous connection of multiple devices. Total load across all four sockets is subject to the unwound or wound current limit, not 13A per socket independently.

  • 25m 1.25mm 3 core PVC cable: 25 metres of cable provides reach across large workshops, site floors, and indoor event spaces from a single mains connection. 1.25mm conductor cross-section within the rated current capacity.

  • Iron frame with carry handle and stable base: Rigid iron frame holds the reel upright during use and storage. Carry handle allows the reel to be transported to the working position without dragging the cable.

  • IP20, indoor and dry use only: IP20 is the minimum classification confirming protection against solid objects greater than 12.5mm only. No water protection of any kind. This reel must not be used outdoors or in damp environments under any circumstances.

Who is this for

Trades and roles:

  • Site managers and general site operatives

  • Electricians specifying temporary site power

  • Workshop managers and factory operatives

  • Event and AV installation teams (indoor)

Industries:

  • Construction (temporary indoor power)

  • Manufacturing and warehousing

  • Events and exhibitions (indoor)

  • Facilities management

 Specifications

Specification Detail
Product Name 25m Cable Reel 240V - 4 Socket Thermal Cutout
SKU EL225
Standard BS EN 61242
Certifications CE, UKCA, RoHS compliant
Safety Class Class I
IP Rating IP20 (indoor and dry conditions only)
Sockets 4 x 13A BS1363
Plug 13A BS plug
Voltage 240V
Frequency 50/60Hz
Maximum Current (fully unwound) 13A (3,120W)
Maximum Current (cable wound) 4A (960W)
Safety Feature Thermal cutout with neon indicator and manual reset
Cable Length 25m
Cable 1.25mm 3 core PVC
Frame Material Iron
Reel Material Polypropylene (PP)
Net Weight 3.5kg

Compatibility

Application or condition Status
Indoor construction site temporary power distribution ✓ Suitable
Large indoor workshops and factory floors ✓ Suitable
Indoor events, exhibitions, and AV installations ✓ Suitable
Site welfare and indoor temporary power ✓ Suitable
Loads up to 13A (3,120W) with cable fully unwound ✓ Suitable
Loads up to 4A (960W) with cable wound on drum ✓ Suitable
Outdoor use of any kind ✗ Not suitable (IP20, no water protection)
Damp or wet indoor environments ✗ Not suitable (IP20)
Loads above 13A when fully unwound ✗ Not permitted
Loads above 4A when cable is partially or fully wound ✗ Not permitted
Permanent wiring installation ✗ Not suitable
Daisy-chaining into another extension lead or reel ✗ Not permitted

 

Who is this for

This cable reel is designed for site operatives, workshop managers, and facilities teams who need to extend 240V power across large indoor spaces from a single mains socket. The 25m cable bridges the gap between a fixed mains point and equipment positioned across a large site floor, warehouse, workshop, or indoor event space where flat extension leads of 5m or less cannot provide the reach required. The thermal cutout provides a safety mechanism for environments where fully unwinding the cable before each use is not always practical, whilst the BS EN 61242 certification confirms the reel meets the standard for temporary power distribution equipment.

Typical applications

  • Running 240V power from a mains socket across a construction site floor to power tools, lighting, and equipment at the far end of an indoor working area.

  • Distributing power from a single fixed socket across a large workshop or factory floor to multiple pieces of equipment without installing additional fixed sockets.

  • Providing temporary power distribution in indoor areas undergoing renovation where fixed socket provision is unavailable or isolated.

  • Powering indoor event and exhibition equipment, lighting rigs, display screens, AV equipment, across large floor areas from a single mains connection.

  • Running temporary 240V supply to site welfare equipment including kettles, microwaves, and space heaters within a large welfare area or building.

  • Providing power to industrial cleaning equipment and floor maintenance machinery requiring reach across large indoor spaces.

How to use

Step 1: Position the reel on a firm, flat surface in a dry indoor location. Check that the full cable path to the working position is clear of pedestrian traffic, vehicle routes, and sharp edges.

Step 2: Unwind the full 25m cable before connecting any load exceeding 4A. If the full cable cannot be unwound and a portion must remain on the drum, all connected loads must total 4A (960W) or less.

Step 3: Insert the 13A plug into the mains socket and switch on. Confirm the neon indicator is illuminated, showing the reel is live.

Step 4: Connect devices to the four sockets. When the cable is fully unwound, combined total load must not exceed 13A (3,120W). When any cable remains on the drum, combined total load must not exceed 4A (960W).

Step 5: If the thermal cutout trips, power cuts and the neon goes off, unplug from the mains immediately, disconnect all devices from the sockets, and allow the reel to cool fully before pressing the red reset button. Do not attempt to reset while the reel is still warm.

Step 6: Before rewinding, switch off and unplug from the mains. Disconnect all devices. Rewind the cable only when the reel is completely de-energised.

Common mistakes

  • Running high-wattage tools with cable wound on the drum: connecting a 2,000W power tool or similar to a wound reel exceeds the 4A wound limit immediately. The thermal cutout will trip within minutes, and repeated tripping under these conditions degrades the cutout over time. Unwind the full cable before connecting significant load.

  • Resetting the thermal cutout without allowing the reel to cool: pressing reset whilst the reel is still hot will cause it to trip again almost immediately. A full cool-down, which may take 20 to 30 minutes, is required before reset will hold.

  • Using in damp, wet, or outdoor conditions: IP20 provides no water protection. Any moisture reaching the cable, sockets, or drum can create an immediate shock hazard. This reel is for dry indoor use only.

  • Rewinding the cable whilst still connected to the mains: always disconnect from the mains before rewinding. A live cable being wound onto the drum creates a coiled conductor under voltage, which is a safety hazard.

  • Daisy-chaining into another extension lead or reel: not permitted under IET Wiring Regulations. The mains socket connection must be a direct, single plug-in connection.

Safety

This cable reel is certified to BS EN 61242, CE and UKCA marked, Class I. Maximum load when fully unwound: 13A (3,120W). Maximum load when wound: 4A (960W). IP20, no water protection, indoor and dry use only. Do not use outdoors or in damp conditions. Do not exceed load limits regardless of whether the thermal cutout is present. The thermal cutout is a protection mechanism, not a substitute for correct use. Always unplug from the mains before rewinding. This reel must not be used as a permanent wiring installation.

Maintenance

Inspect the full 25m cable length for cuts, abrasion, kinking, or crushing before each use. Pay particular attention to the section nearest the plug and the cable entry point on the reel drum, where wear is greatest. Do not use if any cable damage is visible. Inspect the plug for cracking or damage. After use under load, allow the reel to cool before rewinding. Store in a dry indoor location. If the thermal cutout fails to reset after a full cool-down period, withdraw the reel from service, do not attempt to override the cutout.

Frequently Asked Questions

Q: What does the 13A unwound / 4A wound current limit mean and why does it matter?
A: When the cable is fully extended from the drum, the conductors can dissipate the heat generated by current flow into the surrounding air, allowing the full 13A (3,120W) rated load to be used safely. When cable remains wound on the drum, adjacent turns cannot ventilate properly and heat accumulates significantly faster than it can escape. At 13A load with the cable wound, the temperature rise is sufficient to damage the insulation and trigger the thermal cutout within minutes. The 4A (960W) wound limit is the maximum that can be carried safely with the cable on the drum. A 2,000W power drill, a 3,000W heater, or any device above 960W must not be connected unless the cable is fully unwound.

Q: What is the thermal cutout and what should I do when it trips?
A: The thermal cutout is an automatic safety device that disconnects the circuit when the internal temperature of the reel exceeds a safe threshold, typically caused by using the reel under high load with the cable wound. When it trips, the power to all four sockets cuts and the neon indicator goes off. At that point: unplug from the mains immediately, disconnect all devices from the sockets, and allow the reel to cool completely before pressing the red reset button. A full cool-down may take 20 to 30 minutes. Do not attempt to reset while the reel is still warm, the cutout will trip again immediately. If the cutout trips repeatedly at loads within the stated limits, withdraw the reel from service.

Q: What is this cable reel NOT suitable for?
A: This reel is not suitable for outdoor use or any environment where moisture, condensation, or water may reach the cable, sockets, or drum. IP20 provides no water protection of any kind. It must not be used for loads exceeding 13A when fully unwound, or 4A when any cable remains on the drum. It must not be daisy-chained into another extension lead or reel. It must not be used as a permanent wiring installation. The thermal cutout must never be bypassed or overridden.

Q: Can I use this reel outdoors or in a garage?
A: No. IP20 covers protection against solid objects larger than 12.5mm only. It provides zero water or moisture protection. Using this reel outdoors or in any environment where rain, condensation, or water ingress is possible creates an immediate electrical safety risk. For outdoor use, a cable reel with a suitable outdoor IP rating is required.

Q: What is BS EN 61242 and why does it matter for specifying a cable reel?
A: BS EN 61242 is the UK and European standard for cable reels for household and similar purposes. It defines the safety requirements for construction, current ratings, thermal performance, and marking, including the wound and unwound current limits that must be displayed on the product. CE and UKCA marking on a cable reel confirms it has been assessed against these requirements. For RAMS documentation and site safety specifications, BS EN 61242 compliance is the reference to include when specifying temporary 240V power distribution equipment.

Q: Can I use only part of the cable and leave the rest on the drum?
A: Yes, but the load limit that applies when cable remains on the drum is 4A (960W) across all four sockets, regardless of how much cable is unwound. If you need only 5 metres of reach and leave 20 metres on the drum, the 4A wound limit still applies to the entire reel. Low-wattage devices, phone chargers, LED site lights, laptops, are typically within this limit. Power tools, heaters, and most workshop equipment are not.