110V LED festoon lighting kit 22m black rubber cable with 10 IP54 LED fittings and Ceeform plug | CMT Group UK
110V LED festoon lighting kit 22m black rubber cable with 10 IP54 LED fittings and Ceeform plug | CMT Group UK 110V festoon lighting kit 16A Ceeform plug close-up showing IP44 rating and EN60309 marking | CMT Group UK 110V LED festoon lighting kit cable hook detail showing fitting mounting loop for site hanging | CMT Group UK

110V LED festoon lighting kits provide distributed site illumination from 10 IP54 LED fittings on a 22m black rubber cable.

  • 10 x LED fittings, IP54, 5000lm total output
  • 500lm per fitting, 6500K cool white, 120 degree beam, CRI 80
  • 22m black rubber cable, 0.75mm² 2-core
  • 16A 110V yellow Ceeform plug, IP44
  • Class II double insulated, no earth required
  • CE, RoHS, UKCA certified

 

110V LED Festoon Lighting Kit - 22m 10 Lamps

Code
LTFLED25
730+ In Stock

110V LED festoon lighting kits provide distributed site illumination from 10 IP54 LED fittings on a 22m black rubber cable.

  • 10 x LED fittings, IP54, 5000lm total output
  • 500lm per fitting, 6500K cool white, 120 degree beam, CRI 80
  • 22m black rubber cable, 0.75mm² 2-core
  • 16A 110V yellow Ceeform plug, IP44
  • Class II double insulated, no earth required
  • CE, RoHS, UKCA certified

 

£127.72 £106.43
  • Buy 4 for £114.82 £95.68 each and save 10%
  • Buy 8 for £101.92 £84.93 each and save 20%
  • BULK DISCOUNT 4 8
    Price £95.68 £114.82 £84.93 £101.92

Order 1x to earn 106 FASTPoints

Order to earn 106 FASTPoints

Log in to access trade discounts
730+ In Stock

110V LED Festoon Lighting Kit

110V LED festoon lighting kits provide distributed point-of-light illumination across construction corridors, stairwells, and tunnels from 10 IP54-rated LED fittings on a 22m black rubber cable. Each fitting delivers 500 lumens of 6500K cool white light with a 120 degree beam. The 16A 110V Ceeform plug connects directly to a standard site transformer output.

How distributed LED festoon lighting outperforms strip lighting for enclosed site areas

LED strip lighting runs along a surface and illuminates in one direction. In corridors, stairwells, and tunnels where coverage is needed throughout the space rather than across a wall or ceiling, strip lighting leaves shadow gaps at angles the strip doesn't reach. Individual hanging fittings spaced along a festoon cable hang at the centre line of the space. The 120 degree beam from each fitting covers the surrounding area evenly. No shadows between fittings. Consistent illumination along the full 22m run.

Key Features

  • 10 x IP54 LED fittings: Dust protected and water splash resistant individual fittings. Each delivers 500 lumens for a 5000lm total across the full 22m run.

  • 6500K cool white light: Clear, bright illumination suited to construction inspection, navigation, and task work in enclosed site areas.

  • 22m black rubber cable: 0.75mm² 2-core rubber cable rated for site conditions. Fittings are pre-spaced and ready to hang.

  • 16A 110V Ceeform plug: Connects directly to a standard 110V site transformer output. IP44 rated.

  • Class II double insulated: No earth connection required through the lamp body. Meets UK site electrical safety requirements.

  • CE, RoHS, UKCA certified: Meets UK and EU product safety and hazardous substance standards.

  • 30,000-hour LED lifetime: Long service life for temporary installations across extended construction phases.

Who is this for

Trades and roles:

  • Site managers

  • Site electricians

  • M&E contractors

  • Groundwork and civils contractors

  • Tunnelling and infrastructure teams

Industries:

  • Construction

  • Civil engineering

  • M&E and building services

  • Groundworks

  • Tunnelling and infrastructure

 Specifications

Specification Detail  
Product Name 110V LED Festoon Lighting Kit - 22m 10 Lamps
SKU LTFLED25
Total Power 50W
Number of Fittings 10 x LED
IP Rating (Fittings) IP54
Lumen Output per Fitting 500lm
Total Lumen Output 5000lm
Colour Temperature 6500K
CRI (Ra) 80
Beam Angle 120 degrees
LED Lifetime 30,000 hours
Cable Length 22m
Cable 0.75mm² 2-core black rubber
Plug 16A 110V yellow Ceeform
IP Rating (Plug) IP44
Voltage AC 110V, 50/60Hz
Protection Class Class II (double insulated)
Min. Working Temperature +15°C 
Max. Working Temperature +40°C
Certifications CE, RoHS, UKCA

Compatibility

Application or condition Status  
Site corridors, stairwells, and escape routes ✓ Suitable
Tunnels and underground construction areas ✓ Suitable
110V CTE site supply ✓ Suitable
Dusty site environments ✓ Suitable (IP54 fittings)
Water splash and light rain ✓ Suitable (IP54 fittings)
Use at temperatures above +15°C ✓ Suitable
Use below +15°C ✗ Not suitable. Minimum working temperature is +15°C.
230V mains supply connection ✗ Not suitable. 110V only. 230V causes permanent damage and electrical hazard.
Water jets or submersion ✗ Not suitable. IP54 covers splash only.
Explosive or flammable atmospheres ✗ Not suitable. No ATEX certification.

 

Who is this for

This festoon lighting kit suits site managers, site electricians, and M&E contractors who need to provide compliant temporary lighting along enclosed site areas where strip lighting would leave coverage gaps. It is particularly suited to principal contractors lighting internal corridors, stairwells, and escape routes before permanent electrical systems are commissioned, tunnelling and groundwork contractors requiring distributed overhead lighting in enclosed excavations, and M&E teams running temporary lighting through service risers and shafts during installation.

Typical applications

  • Temporary lighting of construction corridors and internal circulation routes before permanent electrical systems are live.

  • Stairwell and escape route lighting during construction phases on multi-storey developments.

  • Tunnel and underground drainage illumination where distributed overhead lighting is needed along the full run.

  • Service riser and shaft lighting during M&E installation on commercial and residential construction projects.

  • Enclosed groundwork and excavation lighting where individual fitting positions suit the working area better than continuous strip.

  • Temporary lighting of basement structures and below-ground areas during structural and fit-out phases.

  • Emergency and access route lighting during construction operations in low-light enclosed areas.

How to use

Step 1: Inspect the cable, all fittings, and the plug for damage before each deployment. Do not use if any damage is found.

Step 2: Confirm the ambient temperature is at or above +15°C before deployment. Do not use below this temperature.

Step 3: Connect the 16A 110V Ceeform plug to a 110V CTE transformer output. Do not connect to 230V supply.

Step 4: Hang the cable along the route using the cable hooks or loops on each fitting. Space fittings evenly and ensure cable hangs clear of sharp edges.

Step 5: Confirm all fittings are illuminated before leaving the installation unattended.

Step 6: Disconnect from the transformer before repositioning, adjusting, or coiling the cable.

Common mistakes

  • Connecting to 230V supply. This kit is 110V only. Connecting to 230V causes permanent damage and creates a fatal electrical hazard.

  • Deploying below +15°C. The minimum working temperature is +15°C. Do not use in cold conditions below this threshold.

  • Coiling the cable while energised. Always disconnect before adjusting, repositioning, or rolling the cable.

  • Hanging on sharp edges or fixings that could damage the rubber cable insulation.

  • Using with damaged fittings or plug. Inspect before every deployment.

Safety

110V only. Connecting to 230V will permanently damage the kit and creates a risk of fatal electric shock. Class II double insulated. No earth required through the lamp body. Do not use below +15°C. IP54 fittings cover dust protection and water splash from any direction but not water jets or submersion. IP44 plug. No ATEX certification. Do not use in explosive or flammable atmospheres. Inspect the full length of cable, all fittings, and the plug before each deployment.

Maintenance

Wipe fittings and cable with a dry cloth after use. Check all fittings and the plug for damage before each deployment. Roll the cable carefully without kinking for storage. Store in a dry location above +15°C. Dispose of in accordance with UK WEEE regulations at end of service life.

Frequently Asked Questions

Q: How are the fittings spaced along the cable?
A: The 10 fittings are pre-wired and spaced at regular intervals along the 22m cable. The spacing distributes the 5000lm total output evenly across the full run. Individual cable hooks or loops on each fitting allow the cable to be hung from nails, fixings, or cable trays along the route.

Q: What does IP54 mean for the lamp fittings?
A: IP54 means each fitting is dust protected (not fully dust-tight but protected against harmful dust ingress) and resistant to water splash from any direction. This covers site dust from cutting and grinding and incidental water splash. It does not cover water jets or submersion.

Q: What is the minimum temperature this kit can be used in?
A: The minimum working temperature is +15°C. Do not deploy this kit in temperatures below +15°C. This is a manufacturer specification and applies to both storage during use and operating conditions. In UK winter conditions, verify the ambient temperature before deployment.

Q: Can I connect multiple kits for a longer run?
A: Linkability has not been confirmed for this kit. Contact the CMT Group sales team before connecting multiple units to confirm compatibility and maximum safe load for your transformer.

Q: What transformer do I need?
A: A 110V CTE site transformer is required. This kit draws 50W. Any 110V site transformer with at least 50W of spare output capacity will power this kit. Confirm the transformer has sufficient capacity if other equipment is running on the same circuit.

Q: Is it suitable for outdoor use?
A: IP54 covers water splash from any direction, making it suitable for light outdoor use and light rain. It is not rated for water jets or sustained heavy rain. It is not rated for use below +15°C, which restricts outdoor use in UK winter conditions. For year-round outdoor use in wet or cold conditions, a higher-rated alternative should be considered.

Q: What certifications does it hold?
A: CE marked, RoHS compliant, and UKCA marked. Meets UK and EU product safety and hazardous substance requirements. Class II double insulated construction.

Q: How long do the LED fittings last?
A: The LED lifetime is rated at 30,000 hours, providing a long service life across extended construction phases and temporary installations.